Ozone Disinfection Concentration Application Standards

Source:

Author:

Release time:2021-12-22 16:30

Reference concentrations for ozone use in space, equipment, containers, preservation, deodorization, and air purification; reference concentration for ozone use in air (1 ppm = 2.14 mg/m³).

I. Reference Concentrations of Ozone for Disinfection, Preservation, Deodorization, and Air Purification in Spaces, Equipment, and Containers

Reference concentration of ozone in air (1 ppm = 2.14 mg/m³)

Use Types Concentration ppm Ozone concentration per cubic meter per hour: mg/h Instructions for use
Disinfection Medical devices 20 50-100 Disinfection time: 60 min at 20 ppm (National Standard YY0215.2-95)
Cold storage warehouse 6-10 15-25 Operate continuously based on reservoir capacity and pollution levels, primarily to eliminate mold.
Food workshop 1.0–1.5 2.5–3.5 Turn on the machine after work each day to deliver O3 gas.
Ward, operating room 10-20 25-50 Turn on the device when disinfection is required and check the total bacterial count according to the standard.
Workwear disinfection 10-20 25-50 The relative humidity is around 90%, so hang your clothes on hangers.
Anti-poison and freshness-preserving General venue 1-2 2.5-5 Turn on regularly
Egg 2-2.5 5-5.5 Supply O3 gas intermittently, turning the machine on 2–3 times per day.
Banana 2.5–3.5 5.5-8
Apple 2.0 5
Vegetables with low chlorophyll 1.5-1 3.5–2.5
Fish, cheese 0.5-1 1.5–2.5
Deodorizing and purifying Morgue 3 7 Turn on the deodorizing function as soon as there’s an odor.
Fish processing plant 3 7 Pollutant gases enter the treatment pipeline, where O3 gas is introduced to oxidize and remove odors. If the odor in the workshop is severe, O3 gas should be added at the workshop’s air intake vents—ideally, the O3 gas itself should not be detectable by smell.
Slaughterhouse 2-3 5-7
Fatty Acid Plant 10 25
Rubber factory 3-10 7-25
Waste disposal 10 25
Wastewater treatment plant 1-2 2.5-5

Excerpted from: Chemical Industry Press, March 2003, “Ozone Technology and Applications”

The following are几点 to keep in mind when using ozone:

01 The "Industrial Hygiene Standards" formulated by China's Ministry of Health in 1979 stipulate that the safe standard for ozone is 0.15 ppm.
02 U.S. standards stipulate that personnel may work for 8 hours at an ozone concentration of 0.1 ppm. (Typically, ozone concentrations in ordinary forest areas can reach 0.1 ppm.)
03 The International Ozone Association stipulates that in professional indoor environments where ozone is used, workers are permitted to stay for up to 10 hours at a concentration of 0.1 ppm.
04 The concentration that elicits a certain response in humans is 0.5–1 ppm, and the permissible exposure time is 1.5 hours. Prolonged exposure may cause discomfort such as dry mouth.
05 Concentrations between 1 and 4 ppm can cause coughing in humans, with an allowable exposure time of 1 hour.
06 Concentrations between 4 and 10 ppm can cause severe coughing, with an allowable exposure time of 20 minutes.
07 Ozone has a half-life of 20 to 50 minutes, and its ultimate decomposition product is oxygen, so it leaves no residual contamination in food.
08 Practice has proven that, after years of using ozone for disinfection and mold prevention, no damage to equipment or device materials has been observed.

Ozone Application—Water Treatment

Currently worldwide, purified water and natural water (such as mountain spring water, mineral water, and groundwater that has been processed through filtration and other procedures) commonly employ ozone disinfection. When applying ozone purification to tap water, the internationally accepted standard is a dissolved concentration of 0.4 mg/L maintained for 4 minutes, resulting in a CT value of 1.6. The table below provides reference values.

Category Metrics Quality-based water supply Purified water Natural water Tap water Swimming pool water
Ozone concentration in water 0.1-0.3mg/L 0.2-0.4mg/L 0.4-0.6mg/L 0.4mg/L 0.2mg/L
Ozone addition amount 1-2g/T 2-3g/T 3-5g/T 3-5g/T 1-2g/T

II. Ozone Space Disinfection Standards and Regulations

1 Food Processing Workshop

The ozone concentration requirement for food processing workshops is relatively low—generally, a level of 2.5 ppm is sufficient. For different food storage rooms, the appropriate ozone concentration should be designed based on the specific substances being stored. The common method for ozone injection is through piping systems; for smaller workshops, an open-air approach can be used.

2 Pharmaceutical factory

2.1 Calculation Method

According to the "Disinfection Technical Specifications" and practical application experience,

For a purification-grade of 300,000, the concentration C = 2.5 ppm = 5 mg/m³;

The Class 100,000 purification level corresponds to a C value of 5 ppm = 10 mg/m³;

The purification level for C is 15 ppm = 30 mg/m³;

Class 100 sampling C = 20 ppm = 40 mg/m³.

Calculation Method: When ozone generators are centrally added via the HVAC system, their selection should be based on the following calculation method: First, calculate the actual ozone disinfection volume, which consists of three components: V = V1 + V2 + V3. Here, V1 represents the volume of the cleanroom space, V2 represents the volume of the air purification system, and V3 represents the volume of air lost during circulation. In practical calculations, V3 is equal to 1.2% of the total airflow rate of the circulation system.

(1) W = C × v / d W: The actual output of the ozone generator to be selected, in units of g/h. C: Ozone dosage per unit volume. V: Actual ozone disinfection volume. d: Ozone decay coefficient, set at 0.42.

(2) If the designed ozone concentration is 5 ppm based on airborne microbial count, the disinfection volume is 10,000 m³, and the supply air flow rate is 100,000 m³/h.

V1 = 10,000 m³

V2 = Negligible

V3 = 100,000 × 1.2% = 1,200

The actual ozone disinfection volume V = V1 + V2 + V3 = 11,200 m³

Ozone dosage W = C × V / d = 5 × 2 × 11,200 / 0.4208 = 266.159 g/h

It is recommended to choose an ozone generator with a production capacity of 280 g/h.

2.2 Built-in Schematic Diagram

The host is typically installed at the downstream end of a medium-efficiency filter or the upstream end of a high-efficiency filter.

Reference materials

1. Ministry of Health, “Technical Specifications for Disinfection,” 1991; 12

2. Technical Supervision Bureau, Ministry of Health, “Methods and Standards for Evaluating Disinfection and Sterilization Effects” GB15981-1995

3. The National Medical Products Administration’s GMP and GSP Committee—“Guidelines for Pharmaceutical Production Validation,” 1994; 4

4. Chemical Industry Press, March 2003, "Ozone Technology and Applications"

5. Li Hanzhong. “Clean Disinfectant—Ozone.” 1996;6

6. Xue Guangbo, Second Military Medical University of the PLA. Practical Disinfection Science. People's Publishing House, 1996; 648–472

7. Shi Jiang et al., “Disinfection and Sterilization,” Military Medical Research Institute, Logistics Department of the Nanjing Military Region, 1989(3):143

8. Bai Xiyao et al., “Ozone and Its Application Research”

9. HACCP China—“Practical Guide to HACCP,” “Guidelines for Implementing the HACCP System in Food Production Enterprises,” and “Consultation and Audit Services for HACCP Systems in Food Production Enterprises”

Key words: Standard, ozone, disinfection, concentration, volume, actual, food, power-on